Amount of Installed Watts Required for Farm Heating Applicants
Application |
Outside temperature above 30°F |
Outside temperature below 30°F |
Estimated kWh used |
Brooding chicks, infrared |
2 1/2-3 watts per chick |
3-4 watts per chick |
2-22.5 per chick per 8 wk |
Brooding chicks, underheat |
1 1/2 watts per chick |
2-2 1/2 watts per chick |
1 per chick per 8 wk |
Lamb brooders |
250 watts per 2 lambs |
250 watts per lamb |
25 per lamb per wk |
Pig brooders |
250 watts per litter |
250 watts per litter |
40 per litter per wk |
Hotbeds |
9-10 watts per sq ft |
9-10 watts per sq ft |
15-20 per 1,000 slips |
Curving sweet potatoes |
300 bu up to 300 bu |
10 watts per bu up to 300 bu |
1-4 kWh per bu per curing period |
|
5 watts per bu, 300-1000 bu |
5 watts per bu, 300-1000 bu |
1-4 kWh per bu per curing period |
|
4 watts per bu over 1000 bu |
4 watts per bu over 1,000 bu |
1-4 kWh per bu per curing period |
Stock watering |
0 |
1 watt per gal |
15 per mo |