Medium Efficiency Cyclone Separator Inlet Duct and Upper Cylinder Height Calculator
Inlet Duct and Upper Cylinder Height Formula
Height of the Inlet Rectangular Square Duct and Upper Cyclone Cylinder (Medium Efficiency):
\[ HD = 0.75 \cdot Dc \]
Where:
- \(HD\) is the height of the inlet duct in meters (m).
- \(Dc\) is the cyclone diameter in meters (m).